Ceiling-Only Sprinkler Designs for Warehouses with Ceiling Heights over 45 ft.
FM Global recently updated their Property Loss Prevention Data Sheet 8-9, Storage of Class 1, 2, 3, 4 and Plastic Commodities (July 2019 edition), to include ceiling-only sprinkler designs for...

Changes to the 2019 edition of NFPA 13, Standard for the Installation of Sprinkler Systems
As the National Fire Protection Association (NFPA) states, "NFPA 13 is the industry benchmark for design and installation of automatic fire sprinkler systems. NFPA 13 addresses sprinkler system...
The Risk-Based Approach of NFPA 99, Health Care Facilities Code
The 1961 Hartford Hospital fire sparked changes in hospital safety procedures and building codes that remain in place more than five decades later. On the afternoon of December 8th, a fire broke out...
NFPA Statistics on Residential Fires
In March of 2017 NFPA published a 54 page document that summarized a history of 485,700 fires by occupancy over a five year period (2010 - 2014). Not surprisingly residential fires accounted for...
Flammable, Combustible & Ignitable Liquid Classification According to NFPA, FM Global and DOT
The Department of Transportation (DOT), NFPA and FM Global are very different in how they classify flammable, combustible & ignitable liquids. NFPA 30, Flammable and Combustible Liquids Code, is...
Significant Changes to the 2016 Edition of NFPA 13
Several important changes are forthcoming in the release of the 2016 edition of NFPA 13, Standard for the Installation of Sprinkler Systems. The most important change is the addition of protection...
Recent Changes to FM Global Property Loss Prevention Data Sheet 8-9, Storage of Class 1, 2, 3, 4 and Plastic Commodities
The recently released June 2015 edition of FM Global Property Loss Prevention Data Sheet 8-9, Storage of Class 1, 2, 3, 4 and Plastic Commodities, contains several changes from the previous version....
UL LISTED PRODUCT VERIFICATION
Several years ago, FM Approvals created their Approval Guide website (www.approvalguide.com), allowing you to verify an FM Approved product. Underwriter's Laboratories (UL) now joins in with their...
FM Data Sheet 1-15, "Roof Mounted Solar Photovoltaic Panels"
The following is a synopsis of the new FM Global Property Loss Prevention Data Sheet 1-15 "Roof Mounted Solar Photovoltaic Panels." This is a new data sheet, issued in July 2014 with October 2014...
Interim Changes in July 2014 to FM Global Data Sheets 7-32 and 7-29
The only notable change in July 2014 to FM Global Data Sheet 7-32, Ignitable Liquid Operations, is additional information for arranging ignitable liquid processes, handling, and use operations to...
Changes to FM Global's Commodity Classification
FM Global updated their Property Loss Prevention Data Sheet (DS) 8-1, Commodity Classification, in April. Their major changes are: Eliminated the sub-classification of plastic commodities (Group...
Flue Spaces in Racks - NFPA 13 vs. FM Global Data Sheet 8-9
Flue spaces are necessary for rack storage arrangements to allow heat from a fire to quickly vent vertically. This is critical in order to help ensure the ceiling-level sprinklers will operate as...